Reusable Spo2 Sensor

Compatible Nellcor Non-OxiMax 3 Meters 9Pin Adult Finger Clip Reusable SpO2 Sensor
Compatible Nellcor Non-OxiMax 3 Meters 9Pin Adult Finger Clip Reusable SpO2 SensorCompatible Nellcor Non-OxiMax 3 Meters 9Pin Adult Finger Clip Reusable SpO2 SensorCompatible Nellcor Non-OxiMax 3 Meters 9Pin Adult Finger Clip Reusable SpO2 SensorCompatible Nellcor Non-OxiMax 3 Meters 9Pin Adult Finger Clip Reusable SpO2 SensorCompatible Nellcor Non-OxiMax 3 Meters 9Pin Adult Finger Clip Reusable SpO2 Sensor

Compatible Nellcor Non-OxiMax 3 Meters 9Pin Adult Finger Clip Reusable SpO2 Sensor

Share
  • Specification

Technical Specifications: 

 

Compatible Brand: NELLCOR 

Compatible Model: N-10, N-180, N-190, N-20, N-30, N-560, N-600, N-600x, N-65, N-85, NPB-190, NPB-195, NPB-3910, NPB-3920, NPB-3930, NPB-3940, NPB-40, NPB-4000, NPB-75, PM10N, Sensors that have Nellcor OxiMax Technology and 9 pins.

Cable Color:Gray

Cable Diameter:4 mm 

Cable Material:TPU Jacket 

Category:SpO2

Certifications:CE, ISO 13485 

Connector Distal:Male 9-Pin D-Sub Purple Connector, Dual Keyed 

Connector Proximal: Adult Finger Clip 

Latex-free:Yes 

Packaging Type:PE Bag

Packaging Unit:1pcs

SpO2 Technology: Nellcor 

Sterile:No

Total Cable Length: 3 meters

Warranty: 12 months 

Weight:0.3lb 


Product Feature:

1) LED 660nm / 905nm, the max output power: 2 mw.

2)SpO2 test range70%~100%Accuracy70%~79% /±3%80%~89% / ±2%90%~100% / ±1%.

3) Pulse rate test range30~245 bpmAccuracy150 bpm -245 bpm /±3 bpm60 bpm -149 bpm/±2 bpmbpm -59 bpm/±1 bpm.

4) Under the environment temperature of 35℃. The maximum allowable temperature of the contact part between a blood oxygen probe and human body shall be no larger than 41℃.

5)Test method for measuring range and measuring precision of SpO2 :Use a supporting device matching the tested spo2 sensor;,connect the tested spo2 sensor and the supporting device, and connect them with a blood oxygen simulation tester.

 

Instructions

This product should be used in accordance with the requirements of supporting the use of models:the compatible equipment,the application part of the degree of shock-proof ,at least for the application of F type. 

 

Date of production: See the product label

Period of use: 3 years

Times of use: 20 times

Storage methods:Put it in a sealed plastic bag after cleaning and drying.The surrounding environment should meet the following conditions:

- Temperature: - 5 ℃ ~ + 40 ℃, relative humidity is not more than 80%, atmospheric pressure: 45kpa to 110kpa

Normal working conditions: temperature: 0 ℃ to 40 ℃;Relative humidity: no more than 80%;Pneumatic: 86kpa to 106kpa.

Warranty service:Please contact the local customer center if you would like to get any after-sale guarantee service information about this product.

Note: Refer to the use of detailed instructions for instrument operation manual when using relevant monitor accessories products.

Compatible Nellcor Non-OxiMax 1 Meter 9Pin Adult Finger Clip Reusable SpO2 Sensor

Compatible Nellcor Non-OxiMax 1 Meter 9Pin Adult Finger Clip Reusable SpO2 Sensor

Compatible Nellcor Non-OxiMax 1 Meter 9Pin Adult Finger Clip Reusable SpO2 Sensor

Compatible Nellcor Non-OxiMax 1 Meter 9Pin Adult Finger Clip Reusable SpO2 Sensor

Compatible Nellcor Non-OxiMax 1 Meter 9Pin Adult Finger Clip Reusable SpO2 Sensor

Compatible Nellcor Non-OxiMax 1 Meter 9Pin Adult Finger Clip Reusable SpO2 Sensor

Compatible Nellcor Non-OxiMax 1 Meter 9Pin Adult Finger Clip Reusable SpO2 Sensor



Contact us
follow us